Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 6: 35069, 2016 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-27725740

RESUMO

Currently, diagnostic testing for Lyme disease is done by determination of the serologic responses to Borrelia burgdorferi antigens, with the exception of the early localized phase of disease where diagnosis must be done clinically. Here, we describe the use of microfluidics technology to develop a multiplexed rapid lab-on-a-chip point of care (POC) assay for the serologic diagnosis of human Lyme disease. Following ELISA screening of 12 candidate antigens, we tested 8 on a microfluidic diagnostic system, called mChip-Ld, using a set of 60 serological samples. The mChip-Ld test, which can be performed in 15 minutes at the point of care, showed promising performance for detection of antibodies to B. burgdorferi using the PPO triplex test (rP100 + PepVF + rOspC-K, AUC of 0.844) compared to a gold-standard reference of culture confirmed clinical samples. The performance is comparable to the commonly used C6 peptide by lab-based ELISA. In addition, the mChip-Ld test showed promising performance for early-stage diagnosis of the disease using the antigen OspC-K (sensitivity and specificity of 84% and 92%, respectively; AUC of 0.877). Overall, this study underscores the potential of using microfluidics to aid the diagnosis of Lyme disease at the point of care.


Assuntos
Anticorpos Antibacterianos/sangue , Doença de Lyme/diagnóstico , Microfluídica/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Testes Sorológicos/métodos , Antígenos de Bactérias/imunologia , Borrelia burgdorferi/imunologia , Humanos , Sensibilidade e Especificidade , Fatores de Tempo
2.
Sci Transl Med ; 7(273): 273re1, 2015 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-25653222

RESUMO

This work demonstrates that a full laboratory-quality immunoassay can be run on a smartphone accessory. This low-cost dongle replicates all mechanical, optical, and electronic functions of a laboratory-based enzyme-linked immunosorbent assay (ELISA) without requiring any stored energy; all necessary power is drawn from a smartphone. Rwandan health care workers used the dongle to test whole blood obtained via fingerprick from 96 patients enrolling into care at prevention of mother-to-child transmission clinics or voluntary counseling and testing centers. The dongle performed a triplexed immunoassay not currently available in a single test format: HIV antibody, treponemal-specific antibody for syphilis, and nontreponemal antibody for active syphilis infection. In a blinded experiment, health care workers obtained diagnostic results in 15 min from our triplex test that rivaled the gold standard of laboratory-based HIV ELISA and rapid plasma reagin (a screening test for syphilis), with sensitivity of 92 to 100% and specificity of 79 to 100%, consistent with needs of current clinical algorithms. Patient preference for the dongle was 97% compared to laboratory-based tests, with most pointing to the convenience of obtaining quick results with a single fingerprick. This work suggests that coupling microfluidics with recent advances in consumer electronics can make certain laboratory-based diagnostics accessible to almost any population with access to smartphones.


Assuntos
Telefone Celular , Doenças Transmissíveis/diagnóstico , Ensaio de Imunoadsorção Enzimática/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Fontes de Energia Elétrica , Desenho de Equipamento , Pesquisas sobre Atenção à Saúde , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Satisfação do Paciente , Ruanda , Sensibilidade e Especificidade
3.
Clin Chem ; 59(4): 629-40, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23327782

RESUMO

BACKGROUND: Collection of epidemiological data and care of patients are hampered by lack of access to laboratory diagnostic equipment and patients' health records in resource-limited settings. We engineered a low-cost mobile device that combines cell-phone and satellite communication technologies with fluid miniaturization techniques for performing all essential ELISA functions. METHODS: We assessed the device's ability to perform HIV serodiagnostic testing in Rwanda and synchronize results in real time with electronic health records. We tested serum, plasma, and whole blood samples collected in Rwanda and on a commercially available sample panel made of mixed antibody titers. RESULTS: HIV testing on 167 Rwandan patients evaluated for HIV, viral hepatitis, and sexually transmitted infections yielded diagnostic sensitivity and specificity of 100% and 99%, respectively. Testing on 40 Rwandan whole-blood samples-using 1 µL of sample per patient-resulted in diagnostic sensitivity and specificity of 100% and 100%. The mobile device also successfully transmitted all whole-blood test results from a Rwandan clinic to a medical records database stored on the cloud. For all samples in the commercial panel, the device produced results in agreement with a leading ELISA test, including detection of weakly positive samples that were missed by existing rapid tests. The device operated autonomously with minimal user input, produced each result 10 times faster than benchtop ELISA, and consumed as little power as a mobile phone. CONCLUSIONS: A low-cost mobile device can perform a blood-based HIV serodiagnostic test with laboratory-level accuracy and real-time synchronization of patient health record data.


Assuntos
Sorodiagnóstico da AIDS/métodos , Telefone Celular , Área Carente de Assistência Médica , Ensaio de Imunoadsorção Enzimática , Humanos , Miniaturização , Ruanda
4.
Nat Med ; 17(8): 1015-9, 2011 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-21804541

RESUMO

One of the great challenges in science and engineering today is to develop technologies to improve the health of people in the poorest regions of the world. Here we integrated new procedures for manufacturing, fluid handling and signal detection in microfluidics into a single, easy-to-use point-of-care (POC) assay that faithfully replicates all steps of ELISA, at a lower total material cost. We performed this 'mChip' assay in Rwanda on hundreds of locally collected human samples. The chip had excellent performance in the diagnosis of HIV using only 1 µl of unprocessed whole blood and an ability to simultaneously diagnose HIV and syphilis with sensitivities and specificities that rival those of reference benchtop assays. Unlike most current rapid tests, the mChip test does not require user interpretation of the signal. Overall, we demonstrate an integrated strategy for miniaturizing complex laboratory assays using microfluidics and nanoparticles to enable POC diagnostics and early detection of infectious diseases in remote settings.


Assuntos
Doenças Transmissíveis/diagnóstico , Imunoensaio/métodos , Microfluídica/instrumentação , Microfluídica/métodos , Países em Desenvolvimento , Infecções por HIV/diagnóstico , Humanos , Ruanda , Sensibilidade e Especificidade , Sífilis/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...